Work History

Work History
Mar 2015 - Present

TESTING ENGINEER

ALFANAR
Testing of numerical relays like ABB REB 650,REQ 650,RED 670,RET 670,REF 615,MiCOM P142,P546,P643,P841,SEL 411L,487E,487V,GE C70,ZIV RELAYS Reviewing of the protection schemes and doing modification according to site condition, review of relay setting calculation and Configuration Doing function test for 380 KV/132 KV C&R Panels and GIS LCC Panels Testing of CT,VT in 380KV and 132 KVGIS and testing of 13.8KV Switchgear Doing SAT with Witness from SEC(Saudi Electric company),Saudi Aramco and Preparing Test reports and Maintaining documents.
Jan 2016 - Present

SAUDI ARAMCO-SHAYBA

SAUDI ARAMCO-SHAYBA
Members: 13.8KV/4.16 KV SWITCHGEAR PETRO RABIGH(ARAMCO) Members: COMMISSIONING OF 380KV/132KV SUBSTATION
Apr 2015 - Present

KV/13.8KV BSP

KV/13.8KV BSP
Members: COMMISSIONING OF 380KV/132 Page2 AL-UQAIR
Apr 2012 - Mar 2015

Electrical Engineer

Saudi Aramco and Preparing
company), Test reports and Maintaining documents. Electrical Engineer-Project at Greenko Energies Pvt Ltd (3 years) commissioning of Twenty Numbers of 1.65MW, 690V/33KV Unit Substation Testing and Commissioning of 100 MW, 33/220KV Outdoor substation including substation equipments such as CTs, PTs, CIRCUIT BREAKER, ISOLATOR, PROTECTIVE AND CONTROL SYSTEMS. Involved in power and control cable laying works as per cable schedule in 33/220kv substation Scheme checking in all C&R panels (SCHNEIDER) in 33/220kv Substation Testing and commissioning of protection Relays such as Numerical
Feb 2013 - Jan 2014

33KV Unit SubStation Saudi Aramco and Preparing

33KV Unit SubStation Saudi Aramco and Preparing
690/ Members: Having commissioned more than 30 nos of 690v/33KV Unit SubStation for the 1.6MW, Wind Turbine Unit ASHBALYAH
Jul 2009 - Mar 2012

Kappa Electricals

Kappa Electricals
Testing Engineer at (2 years 9 months) Checking the turns ratio for CT, PT, and control transformer in their coil stage and making adjustment in turns according to their ratio error #Testing of Transformers, CT, PT in the range of 1.1kv to 33kv Which includes Insulation test, Winding resistance test, Polarity test, Ratio test, Temperature rise test, Knee point voltage test, Partial discharge test in accordance with their respective standards like IEC, IS, ANSI as per customer requirements. #Having strong knowledge in standards like IS 3156, IEC 60044-2 for Page1 PT and IS 2705, IEC 60044-1 for CT. #Experience in design of transformer in accordance with the customer requirement and the economical design with the available materials. #Improving product quality by identifying manufacturing issues, developing cost-effective solutions, and overseeing successful implementation into production. #Corrective and preventive action on NON CONFORMANCE